Bolder automation GmbH
e-mail

Applications

 

Overview

Throughput control

Weight-per-meter control

Blend feeding

Co-extrusion

   

System Features

 

Interface Host

2704 control system

Hardware options

Operation

Internal Functions

GraviMaster 2704

 
Weight-per-meter control
 

Weight-per-meter control via the extruder

Start-up of the extruder and haul-off is done independently in set mode. The weight-per-meter control can be switched on if the line has been adjusted and the working points coordinated with each other.
Run-up to production speed is supported by a ramp function that drives the extruder proportionally in a synchronous mode.
Control of the weight-per-meter functions independently of the working point and adaptively.
 

Weight-per-meter control via the haul-off

The extruder is driven independently and mostly with a constant speed. In this operating mode the heat regulation of the extruder should not be changed.
Deviations of the weight-per-meter are balanced out by the line speed. The adaptive control gently corrects deviations in an optimal time.
A selectable alarm strategy provides for a reliable control mode and for manual operation fulfilling the application requirements.
 
 
Downloads
     
   

Productinformation 2704

     
    Produktinfo Gravimaster 2704
     
   

(pdf-file 536KB)

     
     
 
 
Back
   

Throughput control

   

Weight-per-meter control

   

Blend control

   

Homepage